Error Codes — Cmmo-st-c5-1-diop

| Blink Code | FCT Software Message | Root Cause Analysis | Corrective Action | | :--- | :--- | :--- | :--- | | | Overcurrent (Power stage) | Short circuit in motor cable; defective motor winding; incorrect motor phase resistance. | 1. Disconnect motor cable. Reset error. If error persists, controller is faulty. 2. If error clears, check cable for shorts (continuity test). | | 2 flashes | Overvoltage | DC link voltage exceeded max threshold (typically > 80V DC for CMMO-ST). Regenerative braking from decelerating a large load too fast. | 1. Increase ramp-down time (deceleration). 2. Ensure power supply is regulated (48V +/- 5%). 3. Install an external braking resistor (if supported by your model). | | 3 flashes | Undervoltage | DC link voltage dropped below minimum operating threshold (approx. 16-18V DC). Underpowered PSU; long, thin power cables causing voltage drop. | 1. Verify power supply outputs 24V (logic) and 48V (power). 2. Measure voltage at the controller terminals under load. 3. Increase wire gauge for power lines. | | 4 flashes | Excess position error (Following error) | The motor’s actual position deviated too far from the target position. Mechanical blocking; acceleration too high; motor undersized. | 1. Manually turn the lead screw/actuator by hand. 2. Reduce acceleration ( Fieldbus Acceleration parameter). 3. Increase Position Error Monitoring tolerance (if acceptable). | | 5 flashes | Overtemperature | Internal controller temperature > 85°C. Ambient temp too high; PWM frequency too high; obstructed cooling vents. | 1. Install a cooling fan on the control cabinet. 2. Reduce motor standstill current (Idle current reduction). 3. Move controller to a cooler location. | | 6 flashes | Motor phase failure | One of the two motor phases (A or B) is disconnected. Broken cable; damaged connector pin (M17 or M23). | 1. Visually inspect the stepper motor cable. 2. Use a multimeter: Measure resistance between pins 4 & 5 (Phase A) and 8 & 9 (Phase B). Should be low ohms. 3. Replace cable. | | 7 flashes | Encoder error (Missing encoder) | The feedback encoder (optional on CMMO-ST) is not communicating in closed-loop mode. Wrong encoder type selected in FCT; broken encoder cable. | 1. Check FCT settings: Ensure "Sensorless" is selected if no encoder is present. 2. If using encoder, check 5V supply and A/B track signals. | | 8 flashes | Illegal Hall state | (Less common for stepper) Hall sensors (if used) provide invalid logic combination (e.g., 000 or 111). | 1. Check wiring of Hall sensor interface connector. 2. Replace motor or feedback board. | | 9 flashes | Limit switch error | Both positive and negative limit switches are active simultaneously. Hardware short; incorrectly wired N/O vs N/C switches. | 1. Check DIN inputs for limit 1 and limit 2. 2. Verify logic polarity (Active High vs Active Low) in FCT software. | | 10 flashes | Software overtemperature | The calculated temperature model (based on current and time) exceeds limit, even if actual sensor is cool. High RMS current over long periods. | 1. Reduce duty cycle. 2. Lower the "Motor Peak Current" parameter. 3. Increase pause time between moves. | | Continuous red | Internal device fault (EEPROM/CRC) | Non-volatile memory corruption; firmware crash; severe electrical noise on 24V rail. | 1. Power cycle the entire cabinet (disconnect mains). 2. Reload factory parameters via FCT. 3. Return unit for service. | | Slow blink (1Hz) | Warning: I²t limit reached | The motor is overheating electrically. You are running at peak current for too long. | Reduce acceleration, speed, or load. Allow cooling. The drive will shut down if ignored. | | Fast blink (5Hz) | Start-up error / STO active | Safe Torque Off (STO) function is active (DIN 5 & 6 not receiving 24V). | Apply 24V to both STO inputs (pin 18 & 19). The drive will initialize. |

Ensure the software limits (

If your drive has suddenly halted and you are staring at a blinking LED or a cryptic code on your diagnostic software, this guide will help you translate that error into a solution. cmmo-st-c5-1-diop error codes

Without specific context, here are some speculative insights:

0x01 (Checksum error), 0x02 (Parameter inconsistent) | Blink Code | FCT Software Message |

When your automation system halts due to a , troubleshooting efficiently requires a deep understanding of the specific hardware. The Festo CMMO-ST-C5-1-DIOP Go to product viewer dialog for this item.

The STO (Safe Torque Off) function is triggered. This means power to the motor output stage is safely disconnected, preventing the motor from generating torque. It is a safety feature. Troubleshooting Steps: Reset error

) power inputs. Check for voltage sags when the motor accelerates.

The controller uses specific code letters (A to G) to define how the motor should behave when a particular error occurs. These responses are parameterizable and determine the stop characteristics and whether the output stage is turned off.