Ts1162 Installation Manual Exclusive Here
Following the , here is the correct mechanical installation procedure. Do not deviate.
Minimum of 4 inches (10 cm) of open space around all ventilation ports.
The TS1162 connects to the Challenger panel's LAN terminals. You will typically utilize a 4-core, twisted-pair shielded cable (e.g., Belden 8723). Connects to the LAN + (Positive) terminal. Data-: Connects to the LAN - (Negative) terminal. 12V DC: Connects to the +12V supply terminal. GND: Connects to the GND (Ground) terminal. 2. Shielding and Grounding
Before starting the installation process, make sure you have: ts1162 installation manual exclusive
Whether you are configuring access control for a loading dock or securing a high-traffic entrance, proper deployment ensures long-term operational resilience. This comprehensive, exclusive installation guide covers the exact hardware mounting, RS-485 network wiring, DIP switch configuration, and system commissioning required for the Tecom TS1162. Technical Specifications Overview
Maintained between 32°F and 104°F (0°C to 40°C). Humidity: 10% to 85% non-condensing relative humidity.
: Indicates a total loss of RS-485 communication with the host panel [1.12]. Check the continuity of your D+ and D- wires and ensure the device address matches the polled configuration in the panel database. Following the , here is the correct mechanical
[Challenger Panel LAN Terminal] <====== Twisted/Shielded Pair ======> [TS1162 Keypad Terminal] Positive (+) ---------------------------------------------------- Positive (+) Negative (-) ---------------------------------------------------- Negative (-) Ground (GND) ---------------------------------------------------- Ground (GND) Advanced On-Board Connections
Check for any punctures, water damage, or crushed corners before signing for delivery.
The is a premier security component designed for harsh operational environments. Featuring an impressive IP67 weatherproof rating and a robust molded plastic housing, this device serves as a remote access interface for Tecom Challenger series control panels. It operates at distances up to 1.5 kilometers over an RS-485 data bus. The TS1162 connects to the Challenger panel's LAN terminals
If this TS1162 unit sits at the absolute physical end of a long RS-485 daisy-chain run, you must enable its end-of-line termination to prevent data packet reflections: : Set DIP Switch 8 to ON . Mid-Chain Unit : Set DIP Switch 8 to OFF . Step 4: RS-485 LAN and Peripheral Wiring
Ensure the power source is off and all energy sources are isolated (Lockout/Tagout). 2. Unboxing and Technical Inspection
Connects directly to the Challenger RS-485 LAN .
Double-check all physical mounting hardware and tighten any screws loosened by building vibrations.
Changing P-21 to Level 3 increases power consumption by 8%. Ensure your power supply can deliver a sustained 2.4A at 24V DC.